Mitsubishi MSZ-HC35VA Service Manual Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
42
OPERATING PROCEDURE PHOTOS
5. Removing outdoor fan motor
(1) Remove the cabinet and panels. (Refer to 1.)
(2) Disconnect the connectors for outdoor fan motor.
(3) Remove the propeller nut. (Photo 7)
(4) Remove the propeller. (Photo 7)
(5)
Remove the screws fixing the fan motor. (Photo 7)
(6) Remove the fan motor.
6. Removing the compressor and 4-way valve
(1) Remove the cabinet and panels. (Refer to 1.)
(2) Remove the inverter assembly. (Refer to 2.)
(3) Recover gas from the refrigerant circuit.
NOTE : Recover gas from the pipes until the pres-
sure gauge shows 0 MPa (0 kg/cm
2
).
(4) Detach the welded part of the suction and the dis-
charge pipe connected with compressor.
(5) Remove the nuts of compressor legs.
(6) Remove the compressor.
(7) Detach the welded part of pipes connected with 4-way
valve. (Photo 8)
Photo 6
Photo 7
Photo 8
Welded parts of 4-way valve
Propeller
Screws of the outdoor fan motor
Discharge temperature thermistor
Page view 41