5 - 5
5. PARAMETERS
(2) Detail list
Class No. Symbol Name and Function
Initial
value
Unit
Setting
range
Basic parameters
0 *STY
Command system, regenerative option selection
Used to select the command system and regenerative option.
Selection of command system
(Refer to section 4.2)
0: Absolute value command system
1: Incremental value command system
0
Program edit
0: Valid
1: Invalid
Selection of regenerative option (Refer to section 14.1.1)
0: Not used
(However, this is irrelevant to the MR-J2S-10CL, as it does
not include the built-in regenerative resistor.)
1: FR-RC, FR-BU2
2:MR-RB032
3:MR-RB12
4:MR-RB32
5:MR-RB30
6:MR-RB50(Cooling fan is required)
8:MR-RB31
9:MR-RB51(Cooling fan is required)
If the regenerative option selected is not for use with the
servo amplifier, parameter error occurs.
0000 Refer to
Name
and
function
column.