12 - 1
12. OUTLINE DIMENSION DRAWINGS
12. OUTLINE DIMENSION DRAWINGS
12.1 Servo amplifiers
(1) MR-J2S-10CL to MR-J2S-60CL
MR-J2S-10CL1 to MR-J2S-40CL1
Rating plate
E
N
C
()
[Unit: mm]
6 ( 0.24) mounting hole
A
Approx.70 (2.76)
135 (5.32)
TE2
4(0.16)
B
1
6
8
(
6
.
6
1
)
A
p
p
r
o
x
.
7
(
0
.
2
8
)
1
5
6
(
6
.
1
4
)
6
(
0
.
2
4
)
6
(0.24)
C
N
1
A
OPEN
L1 L2 L3
UVW
MITSUBISHI
C
N
1
B
C
N
2
E
N
C
C
N
3
([Unit: in])
Terminal layout
(Terminal cover open)
PE terminal
(
0
.
7
9
)
6
(
0
.
2
4
)
(Note)
TE1
OPEN
MITSUBISHI
C
N
1
A
C
N
2
C
N
1
B
C
N
3
A
p
p
r
o
x
.
2
0
Variable dimensions
Servo amplifier
A B
Mass
[kg] ([lb])
MR-J2S-10CL (1)
MR-J2S-20CL (1)
50 (1.97) 6 (0.24) 0.7 (1.54)
MR-J2S-40CL (1)
MR-J2S-60CL
70 (2.76) 22 (0.87) 1.1 (2.43)
Note. This data applies to the 3-phase 200 to 230VAC and 1-phase 230VAC power supply models.
TE2
Front
DCPL
21
L
11
PE terminals
Terminal screw: M4
Tightening torque: 1.2 [N m] (10.6 [lb in])
TE1
L
1
UVW
Terminal screw: M4
Tightening torque: 1.2 [N m] (10.6 [lb in])
UVW
Terminal screw: M4
Tightening torque: 1.2 [N m] (10.6 [lb in])
For 3-phase 200 to 230VAC and 1-phase 230VAC For 1-phase 100 to 120VAC
L
2
L
3
L
1 L
2
Terminal signal layout
Mounting Screw
Screw Size:M5
Tightening torque:
3.24[N m]
(28.676 [lb in])