Mitsubishi HD-5000A Instruction Manual Page 163

  • Download
  • Add to my manuals
  • Print
  • Page
    / 356
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 162
5 - 22
5. PARAMETERS
5.2.2 Changing the status display screen
The status display item of the servo amplifier display and the display item of the external digital display
(MR-DP60) shown at power-on can be changed by changing the parameter No.18 (status display
selection) settings. In the initial condition, the servo amplifier display shows the servo motor speed and
the MR-DP60 shows the current position.
For display details, refer to section 7.2.
Parameter No. 18
Status display on servo amplifier displa
y
at power-on
00: Current position (initial value)
01: Command position
02: Command remaining distance
03: Program No.
04: Step No.
05: Cumulative feedback pulses
06: Servo motor speed
07: Droop pulses
08: Override voltage
09: Analog torque limit voltage
0A: Regenerative load ratio
0B: Effective load ratio
0C: Peak load ratio
0D: Instantaneous torque
0E: Within one-revolution position low
0F: Within one-revolution position high
10: ABS counter
11: Load inertia moment ratio
12: Bus voltage
Status display of MR-DP60 at power-on
00: Current position (initial value)
01: Command position
02: Command remaining distance
03: Program No.
04: Step No.
05: Cumulative feedback pulses
06: Servo motor speed
07: Droop pulses
08: Override voltage
09: Analog torque limit voltage
0A: Regenerative load ratio
0B: Effective load ratio
0C: Peak load ratio
0D: Instantaneous torque
0E: Within one-revolution position
0F: ABS counter
10: Load inertia moment ratio
11: Bus voltage