14.1.8 Manual pulse generator (MR-HDP01)
(1) Specifications
Item Specifications
Voltage 4.5 to 13.2VDC
Power supply
Current consumption 60mA max.
Interface Output current max. 20mA for open collector output
Pulse signal form A-phase and B-phase signals with 90°phase difference
Pulse resolution 100pulse / rev
Max. speed Instantaneous max. 600r/min, ordinary 200r/min
Operating temperature range 10 to 60 (14 to 140 )
Storage temperature range 30 to 80
(
22 to 176 )
(2) Connection example
Use an external power supply to supply power to the manual pulse generator.
Manual pulse generato
r
MR-HDP01
SV
A
OV
B
External
power
supply
+5
GND
VDD
OPC
PP
SG
NP
SD
3
11
3
10
2
Plate
Servo amplifier
CN1B
CN1A
(3) Terminal arrangement
Signal name Description
5 to 12V Power input
0V Power and signal common
A A-phase pulse output
+5 to
12V 0V A B
B B-phase pulse output